Search the database of auto parts codes

     

     

     

     

     

    previous

    Page 82 - Catalog auto parts accessorie BOSCH for cars and trucks
    P. 82
    Spare parts cross-references

    AUTO PARTS

    Catalog

    Auto Parts / A80  |  Relays
    
    
            Power relays                                                                            Note:
                                                                                                    Please refer to relay
            For switching starters, automatic preheating systems, motors.                           catalog 1 987 721 076.
            Equipment of forklift trucks and for controlling hydraulic units.
    
    
    
    
    
    
    
             Rated  Fig.  Circuit  Switch-  Switching current Switch function (main relay)  Connection  Dimensions  Part number
             voltage     diagram  ing   S1  )  S2  )  NC    NO      Change-  Screw  Blade  L/W/H
                                          1
                                                2
             V                  poles   A     A                     over                   mm
            Power relay (some with preliminary contact, therefore less contact burn-off).
            Closed construction (polyamide housing); fastening 2 x Ø 5.3 mm.
                                                                                                                3
            12      1    A      –       75    400           •               •       •      75 x 35 x 55  0 332 002 150  )
                                                                                                                3
                                                                                                                  6
                    1    A      –       75    400           •               •       •      75 x 35 x 55  0 332 002 160  )  )
                    1    A      –       75    400           •               •       •      75 x 35 x 55  0 332 002 155
                                                                                                                3
            24      1    A      –       50    200           •               •       •      75 x 35 x 55  0 332 002 250  )
                    1    A      –       50    200           •               •       •      75 x 35 x 55  0 332 002 255
            Power relay with parallel resistor (to suppress inductive interference-voltage peaks).
            Closed construction (polyamide housing); fastening 2 x Ø 5.3 mm.
            24      1    B      –       50    200           •               •       •      75 x 35 x 55  0 332 002 257
            Power relay, closed construction (metal housing); fastening 2 x Ø 5.3 mm.
            12      2    D      1       80    800           •               •              110 x 55 x 60  0 333 006 004
                    2    E      1       80    800           •       •               •      140 x 55 x 56  0 333 006 015  )  )
                                                                                                                  7
                                                                                                                4
                    3    D      1       150   1000          •               •              104 x 56 x 57  0 333 009 004
                                                                                                                7
                    3    D      1       150   1000          •               •              110 x 55 x 60  0 333 009 010  )
            24      2    D      1       80    800           •               •              110 x 55 x 60  0 333 006 006  )
                                                                                                                7
                    2    G      1       100   500   •                       •              110 x 55 x 60  0 333 006 008
                    4    C      2       100   500   •       •               •              95 x 50 x 52  0 333 006 017  )
                                                                                                                7
                    4    F      2       100   800   •       •               •              105 x 50 x 55  0 333 006 010  )
                                                                                                                7
                    3    D      1       150   1000          •               •              104 x 56 x 57  0 333 009 002
                    3    D      1       150   1000          •               •       •      104 x 56 x 57  0 333 009 005
                    3    D      1       150   1000          •               •              104 x 56 x 57  0 333 009 009  )
                                                                                                                7
                    3    D      1       150   1000          •               •       •      106 x 56 x 57  0 333 009 011
                                                                                                                7
                    3    D      1       150   1000          •               •              114 x 56 x 57  0 333 009 017  )
            Power relay, open construction; fastening 2 x Ø 6.4 mm; 4 x Ø 6.4 mm.
            24      5    K      2       250 (3 Min.)        • Single contact  •     •      87 x 62 x 102  0 333 007 002
                    5    H      2       150   1000          • Twin contact  •       •      98 x 57 x 89  0 333 007 004  )
                                                                                                                5
                    6    D      1       230   1500          •               •       •      135 x 70 x 100  0 333 200 010
                    6    E      1       230   1500          •       •               •      135 x 70 x 100  0 333 200 011  )
                                                                                                                4
                    6    D      1       230   1500          •               •       •      135 x 70 x 100  0 333 200 012  )
                                                                                                                5
                    6    I      1       230   1500                  •       •       •      135 x 70 x 128  0 333 201 010
                                                                                                                4
                    6    J      1       230   1500                  •       •       •      135 x 70 x 128  0 333 201 011  )
            80      6    D      1       230   1500          •               •       •      135 x 70 x 100  0 333 200 013
                    6    I      1       230   1500                  •       •       •      135 x 70 x 128  0 333 201 012
                    6    J      1       230   1500                  •       •       •      135 x 70 x 128  0 333 201 013  )
                                                                                                                4
            Degrees of protection according to IEC 60 529                         7 ) Degree of protection
             Designation   Protection against  Protection against  Protection against  Relay   Housing   Terminals
                           contact           foreign bodies    water
            IP 00          no protection     no protection     no protection      0 333 006 006  IP 54   IP 00
            IP 30          with tools etc.   Ø > 2.5 mm        no protection      0 333 006 010  IP 54   IP 00
                           Thickness Ø > 2.5 mm                                   0 333 006 015  IP 33   IP 00
            IP 33          with tools etc.   Ø > 2.5 mm        Spraywater, at angles    0 333 006 017  IP 53  IP 00
                           Thickness Ø > 2.5 mm                up 60° from the    0 333 009 003  IP 54   IP 00
                                                               perpendicular      0 333 009 009  IP 54   IP 00
            IP 53          complete          dust-protected    Spraywater, at angles    0 333 009 010  IP 54  IP 00
                                                               up 60° from the    0 333 009 008  IP 30   IP 00
                                                               perpendicular      0 333 009 017  IP 6K9K  IP 00
            IP 54          complete          dust-protected    Splashwater from
                                                               all directions
            IP 6K9K        complete          dust proof        High pressure/
                                                               steam jet cleaning
            1 )  S1 – Continuous duty          5 )   Fitting position: long edge of baseplate
            2 )  S2 – Short-time duty (1 s)      vertical, max. inclination 10°
            3 )  With preliminary contact      6 )   Switch-on duration 25%, referred to
            4 )  Additional auxiliary relay (changeover),  5 min., i.e. relay may be in operation for
               e.g. for indicator lamps, max. 6 A  1.25 mins max. A pause of 3.75 minutes
                                                 must be maintained afterwards.
    
    
    
            Bosch Automotive Aftermarket                                                                  2010  |  2011 / Auto Parts
    
    
    
                                    
    previous
       77   78   79   80   81   82   83   84   85   86   87
    Current Page
    next

     

     

     

     

     

    next