Search the database of auto parts codes

     

     

     

     

     

    previous

    Page 78 - Catalog auto parts accessorie BOSCH for cars and trucks
    P. 78
    Spare parts cross-references

    AUTO PARTS

    Catalog

    Auto Parts / A76  |  Relays
    
    
            Battery relays
    
    
    
    
    
    
    
    
    
    
    
             1                                  A   31  31b    B    31             2
    
                                                          E  H           E  H
    
    
                                                    31a    86      31a     86
    
    
                                                C   30(31a)    D   30  50 51 31
    
                                                          E  H
    
    
                                                   30(31a)85  86   31a  30a  50a
    
    
    
    
                Cutoff and switching relay,
                 battery changeover relay                                                          30a    31
            Design: open construction. With protective cover.
            Fitting: the terminals must point downwards.
            Fastening: 4 holes Ø 8.4 mm.                                                               E  H
            Connection: screw terminals.
            Dimensions: 124 x 110 x 160 mm.
    
                                                                                                   30     86
    
                                                                                      Cut-off and switching relay 24 V
                                                                                  2    Open construction: Without protective
                                                                                  cover.
                                                                                  Fitting: Terminals must point downwards
                                                                                  Fastening: 4 holes, Ø 8.4 mm.
                                                                                  Connection: Screw terminals.
             Rated      Fig.  Switch-  Circuit  Switching current    Part number  Dimensions: 114 x 78 x 141 mm.
                                                      1
               voltage        ing    diagramm   continuous duty  )  short-time duty   Operating temperature range:
             V                poles           A          A                        –30...+100 °C.
                                                                                  Data for excitation side
            Cutoff and switching relay for disconnecting battery voltage (ground cable)  Max. operating voltage: 30 V
            12          1     2      A        60/200     2500  )     0 333 301 007  Response voltage: ≤ 16 V
                                                             2
                                                             2
            24          1     1      B        200        2500  )     0 333 301 009  Dropout voltage: ≥ 0.5 V
                                     C        300        3500  )     0 333 301 010  Max. make current (at rated voltage) ≤ 4.5 A
                                                             2
            1 ) max. 2 min,  ) max. 1 s                                           Max. holding voltage (at rated voltage) ≤ 0.4 V
                      2
                                                                                  Data for contacts side
            Change-over relay for series and parallel connection of two 12 V batteries in 12 V   Permissible contact loading on terminal 30/30a.
            systems with 24 V starter. For short-time duty.                       Current: ≤ 2,500 A
                                                             3
            12                2      D        75         1500  )     0 333 300 003  Current-flow time: ≤ 1 s
            3 ) max. 5 s                                                          Repeat time: ≥ 60 s
                                                                                  Continuous current:  200 A
                                                                                  Voltage drop: ≤ 10 mV
                                                                                  Test current: 10 A
              Cable dimensions                 Cable length up to   Cable cross-section                  0 333 301 015
              IA voltage drop in the control line   3.2 m      1.5 mm 2
              (ignition switch terminal 86 of cutoff relay)   5.3 m   2.5 mm 2
              must not exceed 0.5 V. The cable cross-   8.5 m   4 mm 2
              section must be matched to the cable    13.0 m   6 mm 2
              length.
              Note:
              Battery relays should be installed as
              close to the batteries as possible, in
              order to keep the connection cables
              short.
    
    
    
            Bosch Automotive Aftermarket                                                                  2010  |  2011 / Auto Parts
    
    
    
                                    